A tankless gas geyser heats water only while a tap is open, so its size is about flow, not storage. A "16 L" geyser heats 16 litres a minute by 25°C. That is plenty for one shower and a basin in summer, but on a frosty Highveld morning the cold water may need a 30°C rise and the same geyser gives less. This calculator sizes for your coldest water and your busiest moment.
How to use it
- Count what runs at the same time at the busiest moment, not every tap in the house. Two showers at once in the morning is the usual sizing point.
- Set the cold water temperature for winter where you live. Water from a rainwater tank or a roof tank can be colder or warmer than mains water.
- Set the minutes per shower and the showers a day for the gas use.
How the sum works
Water flows are typical: 7, 10 or 15 litres a minute for a shower head, 6 for a kitchen tap, 4 for a basin and 12 for a bath. Heat needed = litres a minute × temperature rise × 4.186 ÷ 60, in kW. Geysers are sold by the litres a minute they heat with a 25°C rise, so the size is the next common size above your flow × your rise ÷ 25. Gas assumes the geyser turns 85% of the gas into hot water, with 13.8 kWh in a kilogram of LPG.
Common sizes
| Size | Suits, in winter | Gas at full flow |
|---|---|---|
| 6 L | one basin or a kitchen sink | about 0.9 kg an hour |
| 10 to 12 L | one water saving shower | about 1.5 to 1.8 kg an hour |
| 16 L | one shower and a basin | about 2.4 kg an hour |
| 20 L | two showers on water saving heads | about 3 kg an hour |
| 26 L | two standard showers, or a bath and a shower | about 3.9 kg an hour |
Gas use only while hot water runs. Installed prices are on our gas geysers page.